Re: MIDI SysEx to XL-1

When you say "the manual" do you mean the SysEx manual where the
MULTIMODE VOLUME, for instance, is parameter 131. If so, then you would
need to send a system exclusive message.

On the other hand, do you mean that something that tells you that there
is a channel controller whose id is 131. If the latter, which seems
more likely, then you use CC not RPN or NRPN. I don't think Emu module
support RPNs and NRPNs.

The reason I am confused is that channel volume is more usually on the
controller number 7, not 131.
Regards,
Keith


--- In XL-1@yahoogroups.com, "peamasii" <eduard@...> wrote:
>
> Hi, does anyone know how to control the XL-1 parameters like Channel
> Volume, Arpeggiator Pattern and such? The manual says to use for
example:
>
> id = 131 (03h,01h) min = 0; max = 127
>
> But in my controller I'm supposed to choose CC/RPN/NRPN type of
> control. Do I have to create a MIDI message to some kind, to be able
> to control channel volume remotely?
>
> Eduard
>







Wed Jul 5, 2006 6:39 pm

emigr8
Offline Offline
Send Email Send Email

Forward
Message #2998 of 3078 |
Expand Messages Author Sort by Date

Hi, does anyone know how to control the XL-1 parameters like Channel Volume, Arpeggiator Pattern and such? The manual says to use for example: id = 131...
peamasii
Offline Send Email
Jul 5, 2006
2:46 pm

When you say "the manual" do you mean the SysEx manual where the MULTIMODE VOLUME, for instance, is parameter 131. If so, then you would need to send a system...
Keith Young
emigr8
Offline Send Email
Jul 5, 2006
6:48 pm

I agree with Keith. For what you want you might not need to use sysex. It depends on what you are trying to do. Look in the XL-1 manualy (or any P2K based...
steve_the_composer
steve_the_co...
Offline Send Email
Jul 6, 2006
12:24 pm

OK, thank you, that confirms a lot of my experiments with the XL-1 now. I see that SysEx is a little too complex for the external controller to send out...
peamasii
Offline Send Email
Jul 11, 2006
10:05 pm

USING CONTINUOUS CONTROLLERS: If you have a controller with 16 sliders and you want to use them to mix 16 channels on your XL-1 via midi volume (for example),...
steve_the_composer
steve_the_co...
Offline Send Email
Jul 6, 2006
3:05 pm

Hi, thanks, that's exactly what I meant and then I also understood it was a SysEx message to do it that way, but simpler through CC#7. Very complicated to...
peamasii
Offline Send Email
Jul 11, 2006
9:57 pm
Advanced