Search the web
Sign In
New User? Sign Up
korg_mono-poly · Korg Mono/Poly
? Already a member? Sign in to Yahoo!

Yahoo! Groups Tips

Did you know...
Message search is now enhanced, find messages faster. Take it for a spin.

Best of Y! Groups

   Check them out and nominate your group.
Having problems with message search? Fill out this form to ensure your group is one of the first to be migrated to the new message search system.

Messages

  Messages Help
Advanced
Oscillator Tuning (Scaling)   Message List  
Reply | Forward Message #259 of 482 |
Re: [korg_mono-poly] Re: Oscillator Tuning (Scaling)

Hi Chase

> should which is creating the noise. So now I am changing the
> capacitors, op amps, and voltage regulators and if that does not work,
> then I am out of ideas.
You might try to isolate the error also by disconnecting some boards,
and measure the rest:
'+++' means switch power on
'---' means switch power off

disconnect all boards
+++
check powersupply out with oscilloscope
---
connect KLM-356 (uP board) to powersupply and keyboard to KLM-356
(perhaps also the 353 with the keyboardmode switches is required)
+++
check the CVs at the connector pins 27-1 to 27-4 with oscilloscope
---
connect the VCO-board
+++
check the CVs at the connector pins 1,3, 9, and 11 of IC-7 with
oscilloscope.
check the outputs of IC-22 (opamp after Ext VCO in) with oscilloscope.
check at the four summing points for VCO-CVs
check the output of all four VCOs separately.
---
add VCF board
+++
Check again the output of the VCOs

and so on....

If the constant FM appears, the let the constellation as it is, but go
back in the measurement chain to check how far 'back' the FM can be
traced (e.g. already on VCO board, but not at the uP-board-output).

I don't remember wether the ICs originally are socketed. But if they
are, you might also remove some relevant ICs.

Florian



Sun Dec 23, 2007 5:59 pm

florian_anwa...
Offline Offline
Send Email Send Email

Forward
Message #259 of 482 |
Expand Messages Author Sort by Date

Hello, I recently acquired a mono/poly that has oscillator 1 out of scale. I've read the calibration procedure in the service many and I'm not sure if I am...
plus_321
Offline Send Email
Sep 9, 2007
11:59 pm

Maybe you should contact a professional synth repair man. It will ofcourse cost a little, but save your own time to a profitable work....
envia94
Offline Send Email
Dec 23, 2007
11:19 am

Yeah, I did that awhile ago but in the course of him fixing that problem another problem arose and I ran out of money so now I have to fix it myself. Now I...
Chase Smith
plus_321
Offline Send Email
Dec 23, 2007
12:45 pm

Hi Chase ... You might try to isolate the error also by disconnecting some boards, and measure the rest: '+++' means switch power on '---' means switch power...
Florian Anwander
florian_anwa...
Offline Send Email
Dec 23, 2007
5:58 pm

Hello, Upon the previous suggestion, I was able to get a bit closer to the problem, but still no solution. However, I am hoping that my new information makes...
Chase Smith
plus_321
Offline Send Email
Dec 27, 2007
3:21 am

Change your electrolytics, maybe. I had to replace mine on my filters a couple years ago. If you're having global problems, maybe it's your power supply. Maybe...
Scott Deyo
tsomneevich
Offline Send Email
Dec 27, 2007
3:29 am

Hello, Upon the previous suggestion, I was able to get a bit closer to the problem, but still no solution. However, I am hoping that my new information makes...
Chase Smith
plus_321
Offline Send Email
Dec 27, 2007
3:29 am
Advanced